The JXM-IO-EW30 expansion module is the universal distributed component for mobile machines.
With its balanced I/O configuration, it can handle almost all distributed tasks. Communication with the JXM-IO-EW30 takes place via CANopen®. This allows for integration into conventional CAN networks used in mobile machines.
The rugged housing, use of cable glands and connection via WAGO MCS mini HD allows a flexible wiring and guarantees highest reliability in harsh environment.
Operating voltage range | DC 8 ... 32 V, ECU voltage supplied separately |
Operating/storage temperature range | -25 … +85 °C / -40 … +85 °C |
CAN Interfaces | 1 CANopen® |
Maximum number of inputs/outputs | 26 |
Inputs | |
Analog | 8; 0 … 5 V (2x 0 ... 10 V adjustable via DIP switch) / 0 … 20 mA, can be configured individually; resolution: 12 bit, input impedance 35 kΩ, load resistor 120 Ω |
Digital/frequency | 4 active-high, input impedance; 5.6 kΩ, 0.1 Hz ... 10 kHz |
Digital/CAN coding | 2 CAN ID coding, tri-state |
Outputs with diagnostics capability (short-circuit, no-load) | |
PWM, precision current measurement | 4; 3 A, max. 1.5 kHz, dithering, current controlled, diagnostics-capable, short-circuit proof; alternatively to be used as digital active-low input, input impedance 10 kΩ; digital output 3 A; PNP input |
PWM | 6; 7 A, max. 1.5 kHz, dithering, diagnostics capable, short-circuit-proof; alternatively to be used as digital active-low input, input impedance 10 kΩ; digital output 7 A; PNP input |
Digital (50 % ON period) | 4; 3 A high-side, diagnostics capable, short-circuit proof, (with 50 % ON period); alternatively to be used as digital active-low input, input impedance 10 kΩ; PNP input |
Sensor supply | 3 fused VBAT supplies for sensors |
Maximum permissible total current | 25 A |
Degree of protection | IP66 |
Vibration | ISO 16750-3 |
Shock | ISO 16750-3 |
Certifications | ECE R10 E1, CE ISO 14982 |
Maximum installation height | 2000 m (above sea level) |
Reverse polarity protection | Yes, external fuse |
Output diagnostics | Short-circuit, cable break |
Sales
+49 (7141) 2550-663
sales@bucherautomation.com
Hotline
more
hotline@bucherautomation.com
Further information
(6.76 MB)Catalog "Industrial Automation"
(5.01 MB)Catalog "Mobile Automation"