We automate your success.

Servomotors

Description

Going with the servo amplifiers of the JetMove series are Jetter motors featuring DC link voltages of DC 24 to 560 V and a great selection of motor windings.

By an appropriate combination you can achieve the speed which best fits your application and which also makes the most of the rated current of the servo amplifier used. All Jetter AG servo motors are extremely rugged 3-phase synchronous motors with UL certification. They are available in several series: JL, JK, JH, and JHN.

Numerous options for connector outlets, degrees of protection and encoder design are available. Along with this comprehensive range of motors, we offer pre-fabricated and tested servo cables and corresponding gearboxes.

JL motors
JL motors cover the range from 0.1 Nm (JL1) to 115 Nm (JL8). They feature classic winding technology.

JHN motors
The segment winding technology on JHN motors has been automated and the motor structure optimized, providing high power density in a very compact design. The motors are available in sizes 2 to 7 with 0.28 Nm to 60 Nm.

JHQ motors
The JHQ motors comprise frame sizes 2-5 (JH) and 2-8 (JL). Further they have got two intermediate sizes, 23 and 45. Their high torque constant makes them an alternative to the so far used JL and JH motors if an adequate quantity of them is ordered.

Key benefits of servo motors by Jetter AG:

  • All motors have UL certification for the USA and Canada  (except for JL1) and can therefore be exported to those countries.
  • They also have reduced circular runout tolerance as standard, resulting in a smooth-running system.
  • The motor windings are optimized to suit Jetter AG servo amplifiers and their DC link voltages (or supply voltages), which noticeably improves system efficiency.
  • JHN motors excel in terms of highly compact design combined with high torque. This allows for installation in smaller machines.
  • There is a multitude of encoder and connector options for Jetter motors giving you greater flexibility in engineering and manufacturing a plant.

  Flange 1 Flange 12 Flange 2 Flange 22 Flange 23 Flange 24 Flange 3 Flange 4 Flange 45 Flange 5 Flange 51 Flange 6 Flange 7 Flange 71 Flange 8
CE and UL certification (USA + Canada), cURus* - x x x x x x x x x x x x x x
Isolation class F, 2-pin resolver x x x x x x x x x x x x x x x
Temperature monitoring KTY83-110 with HDSL PT1000 PTC PTC KTY83-110 KTY83-110 KTY83-110 KTY83-110 KTY83-110 KTY83-110 KTY83-110 KTY83-110 KTY83-110 KTY83-110 KTY83-110 KTY83-110 KTY83-110
Degree of protection IP64 IP65 IP64/IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65
Runout (R) tolerance to DIN 42955 (for JHQ as option) x x x x x x x x x x x x x x x
                               
JL series (Nm) 0,1 ... 0,2 - 0,2 ... 0,8 - - - 0,65 ... 3,0 5,3 ... 7,5 - 10,5 ... 22,0 - 19,0 ... 29,0 32,0 ... 40,0 - 40,0 ... 115,0
JHN series (Nm) - - 0,28 ... 0,95 - - - 1,15 ... 4,8 5,1 ... 11,3 - 12,0 ... 24,0 - 18,0 ... 44,0 30,0 ... 60,0 - -
JHQ series (Nm) - 0,18 ... 0,32 0,25 ... 1,25 0,7 ... 1,4 0,6 ... 3,0 0,7 ... 2,7 1,35 ... 4,5 4,0 ... 10,0 6,0 ... 14,0 4,5 ... 26,0 29 ... 38 20,0 ... 28,0 36,0 ... 42,0 56 ... 80 42,0 ... 73,0/81,0 ... 120,0
                               
Length (incl. resolver, without brake) JL (mm) 81 ... 111 - 98 ... 143 - - - 109 ... 181 176 ... 221 - 226 ... 311 - 242 ... 317 264 ... 294 - 310 ... 514
Length (incl. resolver, without brake) JHN (mm) - - 67 ... 112 - - - 82 ... 172 113 ... 203 - 157 ... 247 - 158 ... 258 181 ... 271 - -
Length (incl. resolver, without brake) JHQ (mm) - 63 ... 77 87 ... 135 84 ... 104 112 ... 182 86 ... 120 122 ... 180 150 ... 214 168 ... 233 148 ... 298 338 ... 405 195 ... 218 240 ... 263 308 ... 414 293 ... 493
                               
Flange size/centering/hole circle JL (mm) 37/25/41,5 - 55/40/63 - - - 86/80/100 98/95/115 - 142/130/165 - 190/180/215 190/180/215 - 240/230/265
Flange size/centering/hole circle JHN (mm) - - 55/40/63 - - - 86/80/100 98/95/115 - 142/130/165 - 190/180/215 190/180/215 - -
Flange size/centering/hole circle JHQ (mm) - 40/30/46 58/40/63 60/50/70 70/60/75 80/70/90 91,3/80/100 100/95/115 116/110/130 142/130/165 142/130/165 190/180/215 190/180/215 190/180/215 240/230/265
                               
Shaft JL (mm) 6 x 16 - 9 x 24 - - - 14 x 30 19 x 40 - 24 x 50 - 24 x 50 28 x 58 - 38 x 80/42 x 110
Shaft JHN (mm) - - 9 x 20 - - - 14 x 30 19 x 40 - 24 x 50 42 x 110 24 x 50 28 x 58 - -
Shaft JHQ (mm) - 8 x 25 9 x 20 14 x 30 11 x 23/14 x 30 16 x 40 14 x 30 19 x 40 19 x 40/24 x 50 24 x 50 28 x 58 24 x 50 28 x 58 38 x 80 38 x 80/42 x 110
                               
Option: Brake, keyway to DIN 6885 (for JL, JHN, JHQ) x x x x x x x x x x x x x x x
Option: Degree of protection IP67 with shaft seal (for JL, JHN, JHQ) - x x x x x x x x x x x x x x
Option HIPERFACE® SEx37, SKx36, SEx52, SRx50 (as of flange 3) (for JL, JHN, JHQ) - x x x x x x x x x x x x x x
Option HIPERFACE DSL® EEx37, EKx36 (for JHQ) - x x x x x x x x x x x x x x
Connector output option: Drive end, non-drive end, rotatable (for JL, JHN, JHQ) - x x x x x x x x x x x x x x
Option Potentially explosive areas ATEX zone 2 and 22: II 3G Ex nA IIC T155 °C / II 3D Ex tc IIIC T135 °C (for JL, JHN, JHQ) - x x x x x x x x x x x x x x
Electrical connection option: Cable screw connection, cable, connector (for JL, JHN) x - x - - - - - - - - - - - -
Options: Special shafts, other encoders, reinforced bearings, special ball-bearing grease, separately driven fan, etc. On request On request On request On request On request On request On request On request On request On request On request On request On request On request On request