Going with the servo amplifiers of the JetMove series are Jetter motors featuring DC link voltages of DC 24 to 560 V and a great selection of motor windings.
By an appropriate combination you can achieve the speed which best fits your application and which also makes the most of the rated current of the servo amplifier used. All Jetter AG servo motors are extremely rugged 3-phase synchronous motors with UL certification. They are available in several series: JL, JK, JH, and JHN.
Numerous options for connector outlets, degrees of protection and encoder design are available. Along with this comprehensive range of motors, we offer pre-fabricated and tested servo cables and corresponding gearboxes.
JL motors
JL motors cover the range from 0.1 Nm (JL1) to 115 Nm (JL8). They feature classic winding technology.
JHN motors
The segment winding technology on JHN motors has been automated and the motor structure optimized, providing high power density in a very compact design. The motors are available in sizes 2 to 7 with 0.28 Nm to 60 Nm.
JHQ motors
The JHQ motors comprise frame sizes 2-5 (JH) and 2-8 (JL). Further they have got two intermediate sizes, 23 and 45. Their high torque constant makes them an alternative to the so far used JL and JH motors if an adequate quantity of them is ordered.
Key benefits of servo motors by Jetter AG:
Flange 1 | Flange 12 | Flange 2 | Flange 22 | Flange 23 | Flange 24 | Flange 3 | Flange 4 | Flange 45 | Flange 5 | Flange 51 | Flange 6 | Flange 7 | Flange 71 | Flange 8 | |
CE and UL certification (USA + Canada), cURus* | - | x | x | x | x | x | x | x | x | x | x | x | x | x | x |
Isolation class F, 2-pin resolver | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x |
Temperature monitoring KTY83-110 with HDSL PT1000 | PTC | PTC | KTY83-110 | KTY83-110 | KTY83-110 | KTY83-110 | KTY83-110 | KTY83-110 | KTY83-110 | KTY83-110 | KTY83-110 | KTY83-110 | KTY83-110 | KTY83-110 | KTY83-110 |
Degree of protection | IP64 | IP65 | IP64/IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 |
Runout (R) tolerance to DIN 42955 (for JHQ as option) | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x |
JL series (Nm) | 0,1 ... 0,2 | - | 0,2 ... 0,8 | - | - | - | 0,65 ... 3,0 | 5,3 ... 7,5 | - | 10,5 ... 22,0 | - | 19,0 ... 29,0 | 32,0 ... 40,0 | - | 40,0 ... 115,0 |
JHN series (Nm) | - | - | 0,28 ... 0,95 | - | - | - | 1,15 ... 4,8 | 5,1 ... 11,3 | - | 12,0 ... 24,0 | - | 18,0 ... 44,0 | 30,0 ... 60,0 | - | - |
JHQ series (Nm) | - | 0,18 ... 0,32 | 0,25 ... 1,25 | 0,7 ... 1,4 | 0,6 ... 3,0 | 0,7 ... 2,7 | 1,35 ... 4,5 | 4,0 ... 10,0 | 6,0 ... 14,0 | 4,5 ... 26,0 | 29 ... 38 | 20,0 ... 28,0 | 36,0 ... 42,0 | 56 ... 80 | 42,0 ... 73,0/81,0 ... 120,0 |
Length (incl. resolver, without brake) JL (mm) | 81 ... 111 | - | 98 ... 143 | - | - | - | 109 ... 181 | 176 ... 221 | - | 226 ... 311 | - | 242 ... 317 | 264 ... 294 | - | 310 ... 514 |
Length (incl. resolver, without brake) JHN (mm) | - | - | 67 ... 112 | - | - | - | 82 ... 172 | 113 ... 203 | - | 157 ... 247 | - | 158 ... 258 | 181 ... 271 | - | - |
Length (incl. resolver, without brake) JHQ (mm) | - | 63 ... 77 | 87 ... 135 | 84 ... 104 | 112 ... 182 | 86 ... 120 | 122 ... 180 | 150 ... 214 | 168 ... 233 | 148 ... 298 | 338 ... 405 | 195 ... 218 | 240 ... 263 | 308 ... 414 | 293 ... 493 |
Flange size/centering/hole circle JL (mm) | 37/25/41,5 | - | 55/40/63 | - | - | - | 86/80/100 | 98/95/115 | - | 142/130/165 | - | 190/180/215 | 190/180/215 | - | 240/230/265 |
Flange size/centering/hole circle JHN (mm) | - | - | 55/40/63 | - | - | - | 86/80/100 | 98/95/115 | - | 142/130/165 | - | 190/180/215 | 190/180/215 | - | - |
Flange size/centering/hole circle JHQ (mm) | - | 40/30/46 | 58/40/63 | 60/50/70 | 70/60/75 | 80/70/90 | 91,3/80/100 | 100/95/115 | 116/110/130 | 142/130/165 | 142/130/165 | 190/180/215 | 190/180/215 | 190/180/215 | 240/230/265 |
Shaft JL (mm) | 6 x 16 | - | 9 x 24 | - | - | - | 14 x 30 | 19 x 40 | - | 24 x 50 | - | 24 x 50 | 28 x 58 | - | 38 x 80/42 x 110 |
Shaft JHN (mm) | - | - | 9 x 20 | - | - | - | 14 x 30 | 19 x 40 | - | 24 x 50 | 42 x 110 | 24 x 50 | 28 x 58 | - | - |
Shaft JHQ (mm) | - | 8 x 25 | 9 x 20 | 14 x 30 | 11 x 23/14 x 30 | 16 x 40 | 14 x 30 | 19 x 40 | 19 x 40/24 x 50 | 24 x 50 | 28 x 58 | 24 x 50 | 28 x 58 | 38 x 80 | 38 x 80/42 x 110 |
Option: Brake, keyway to DIN 6885 (for JL, JHN, JHQ) | x | x | x | x | x | x | x | x | x | x | x | x | x | x | x |
Option: Degree of protection IP67 with shaft seal (for JL, JHN, JHQ) | - | x | x | x | x | x | x | x | x | x | x | x | x | x | x |
Option HIPERFACE® SEx37, SKx36, SEx52, SRx50 (as of flange 3) (for JL, JHN, JHQ) | - | x | x | x | x | x | x | x | x | x | x | x | x | x | x |
Option HIPERFACE DSL® EEx37, EKx36 (for JHQ) | - | x | x | x | x | x | x | x | x | x | x | x | x | x | x |
Connector output option: Drive end, non-drive end, rotatable (for JL, JHN, JHQ) | - | x | x | x | x | x | x | x | x | x | x | x | x | x | x |
Option Potentially explosive areas ATEX zone 2 and 22: II 3G Ex nA IIC T155 °C / II 3D Ex tc IIIC T135 °C (for JL, JHN, JHQ) | - | x | x | x | x | x | x | x | x | x | x | x | x | x | x |
Electrical connection option: Cable screw connection, cable, connector (for JL, JHN) | x | - | x | - | - | - | - | - | - | - | - | - | - | - | - |
Options: Special shafts, other encoders, reinforced bearings, special ball-bearing grease, separately driven fan, etc. | On request | On request | On request | On request | On request | On request | On request | On request | On request | On request | On request | On request | On request | On request | On request |