We automate your success.

JXM-IO-E02

Description

The large number of individually configurable I/O connections, the high total current as well as the rugged and compact design make the JXM-IO-E02 a multi-purpose CAN remote node.

The supply voltage of the inputs and outputs is divided into Standard Feed and Protected Feed, and it allows for independent deactivation of inputs and outputs in safety applications.

The CAN ID of the I/O node can be defined via external connection of digital inputs. This way, up to nine nodes can be addressed within one system without further configuration measures to be taken.

 

Features

  • Flexible I/O configuration
  • The CAN addresses can be configured via wiring harness
  • Compact and rugged enclosure
  • High degree of protection IP66/IP68

Technical Data

Operating voltage DC 8 ... 32 V, separate load voltage
Operating/storage temperature -40 … +85 °C
Ports and interfaces  
CAN 1 CANopen®
Max. number of inputs/outputs 32
Inputs  
Analog 4, 0 … 5 V/0 … VBAT/0 … 20 mA/4 … 20 mA, can be configured individually, resolution: 10 bits, input impedance: 50 kΩ, load resistor: 240 Ω
Digital 5 Active low/high, can be configured individually, input impedance 2 kΩ
Frequency 2, Active low/high, can be configured individually, 5 Hz … 20 kHz, period 62.5 ns; Alternative usage: Digital input active-high, input impedance 2 kΩ
Outputs  
Analog 1, 0 … VBAT, 10-bit resolution, short-circuit detection, peak current 100 mA
Digital 8, 2.5 A high-side, diagnostics capability, short-circuit proof; Alternative usage: Digital input active-high, input impedance 100 kO; 2, 2.5 A high-side, diagnostics capability, short-circuit proof; Alternative usage: Digital input active-low, input impedance 100 kΩ; 8, 5 A high-side, diagnostics capability, short-circuit proof, supplied via Protected Feed; Alternative usage: Digital input active-high, input impedance 100 kΩ
PWM 3, 2.5 A, max. 2 kHz, resolution: 8 bits, current-controlled, capable of diagnostics; Alternative usage: Digital output 2.5 A
H-bridge 1, 2.5 A
Power supply 1, 5 V power supply for sensors
Max. permitted total current 40 A
Degree of protection IP66/IP68
Vibration DIN EN 60068-2-64, Cat. 2
Shock DIN EN 60068-2-64, 30g
Protection against polarity reversal Yes

Your contact person

Sales Department
  +49 (7141) 2550-663
  sales@bucherautomation.com

Further information

Quicklinks

Your contact person