Description

In JCM-529, circuit parts for modular expansion of the JCM-521 series have been translated into a concept comprising fixed I/O configuration. This makes it a cost-effective solution keeping up the performance features of the JCM-521 series. Layout-reuse technology enables adjustments to be made in PCB assembly at low cost. 103 I/O connections are available in the fully equipped configuration.

An optional diagnostics display with controls features production data display, diagnostics and configuration on the spot without additional supporting devices such as PC or testing devices still being needed.

Features

  • 32-bit controller, 500 MHz
  • Programming to IEC 61131-3 STX or in C/C++
  • Fixed I/O configuration featuring modularizing varieties
  • CAN, LIN, Ethernet and RS232 port for high connectivity
  • Built-in controls with graphic display

Technical Data

CPU ARM 11, 32-bit, 500 MHz
Memory: RAM - Application - Non-volatile 64 MB RAM – 512 MB Flash – 64 kB MRAM
Peripheral devices FPGA
Programming IEC 61131-3 STX, C/C++
Operating system WinCE 6.0
Operating voltage DC 8 ... 30 V, separate load voltage
Operating/storage temperature -40 … +85 °C
Ports and interfaces
Ethernet 1 Up to 100 Mbit/s
CAN 2, 125 kB/s to 1 MB/s; CANopen®, SAE J1939, ISOBUS 11783; Jetter CAN-Prim for customer-specific proprietary protocols
RS232 1
LIN 4
Operation and diagnostics (optional) 1 LCD graphics display; 6 LEDs red, green; 3 Keys
RTC Option
Number of inputs/outputs 103
Inputs
Analog 58, 0 … 5.7 V/0 … 15 V/0 ... 20 mA, can be configured individually, capable of diagnostics, resolution: 12 bits, input impedance: 50 ... 100 kΩ, load resistor: 120 Ω, Alternative usage:NAMUR input with a bias voltage of 8.2 V; Digital input active-high, input impedance 50 ... 100 kO; Frequency input 0.1 ... 10 kHz, period > 1 µs, input impedance 50 … 100 kΩ; Input for gate time measuring 0.1 ... 10 s; Interruptible input, 16-bit time stamp, resolution 1 µs
Outputs
PWM 4, 3.8 A; current control 1 %; 10 Hz ... 1 kHz; Alternative usage: Digital output 3.5 A, high-side; 34, 3.8 A; current control 6 %; 10 Hz ... 1 kHz; Alternative usage: Digital output 3.5 A, high-side; 5, 0.5 A; 10 Hz … 1 kHz; Alternative usage: Digital output 2.0 A, high-side
H-bridge 2, 3.8 A; current control 6 %; 10 Hz ... 1 kHz; Alternative usage: 4x digital output 3.8 A high-side; 4x digital output 3.8 A low-side; Max. permitted total current 40 A
Diagnostic functions Total current monitoring, protection against polarity reversal, overload and no-load detection, all I/Os are protected against short circuit to GND and VBAT
Degree of protection IP65
Vibration DIN EN 60068-2-64, Cat. 2
Shock DIN EN 60068-2-64, 30g
Protection against polarity reversal Yes