We automate your success.

JetControlMobile 511

Description

The semi-modular compact controller JetControlMobile 511 is based on the modular JCM-521 series. Due to its vast I/O capacity featuring high-performance H-bridges, PWM outputs, flexibly applicable inputs and high total ampacity, even its basic configuration is already sufficient for numerous applications. Besides hydraulic actuators, it can even directly control electric motors. Extensibility by two MX modules allows for easily adjusting to a great variety of functions and applications.

Besides standard ports and interfaces, the JCM-511 is equipped with inputs apt for NAMUR, as well as with a LIN port. This way, it can be integrated into almost any systems architecture.

The high-level language STX to IEC 61131-3 lets you realize virtually any control task. Programming in C/C++ is possible, too.

Features

  • 32-bit controller, 500 MHz
  • Programming to IEC 61131-3 STX or in C/C++
  • Partially modular I/O configuration for high flexibility
  • CAN, USB, LIN and RS232 port for high connectivity
  • Compact design

Technical Data

CPU ARM 11, 32-bit, 500 MHz
Memory: RAM - Application - Non-volatile 128 MB RAM – 512 MB Flash – 128 kB MRAM
Peripheral devices FPGA
Programming IEC 61131-3 STX, C/C++
Operating system WinCE 6.0
Operating voltage DC 8 ... 32 V, separate load voltage
Operating/storage temperature -40 … +85 °C
Ports and interfaces  
CAN 2, 125 kB/s to 1 MB/s; CANopen®, SAE J1939, ISOBUS 11783; Jetter CAN-Prim for customer-specific proprietary protocols
USB 1
RS232 1
LIN 1
Ethernet 1 (option)
Operation and diagnostics 2 status LEDs
RTC Option
Max. number of inputs/outputs 40
Inputs (basic configuration)  
Analog 8, 0 … 5.7 V/0 … 22 mA, can be configured individually resolution: 12 bits, input impedance: 75 kΩ, load resistor: 120 Ω; Alternative usage: NAMUR input with a bias voltage of 8.2 V; Digital input active-high, input impedance 50 kO; Frequency input, 0.1 ... 10 kHz, period > 1 µs
Digital 8 Active-high, input impedance 50 kO; Alternative usage: Frequency input, 0.1 ... 10 kHz, period > 1 µs
Outputs (basic configuration)  
PWM 4, 3.5 A; current control 1 %; 10 Hz ... 1 kHz; Alternative usage: Digital output 3.5 A, high-side
H-bridge 2, 15 A; 10 Hz … 1 kHz; Alternative usage: 4x PWM 10 Hz … 1 kHz, 15 A; 4x digital output 15 A high-side; 4x digital output 15 A low-side
Maximum number of MX modules (expansion modules) 2 Up to 8 inputs/outputs per MX module
Power supply - External sensors 5 V or 10 V, can be toggled via software configuration
Max. permitted total current 30 A, temporarily 60 A
Safety relay in the load circuit Yes, PWM outputs can be disabled
Diagnostics Total current monitoring, protection against polarity reversal, overload and no-load detection, all I/Os are protected against short circuit to GND and VBAT
Degree of protection IP65
Vibration DIN EN 60068-2-64, Cat. 2
Shock DIN EN 60068-2-64, 30g
Protection against polarity reversal Yes

Your contact person

Sales Department
  +49 (7141) 2550-663
  sales@bucherautomation.com

Your contact person