JetControlMobile 231

Description

Despite its very compact dimensions, the JetControlMobile 231 compact controller has a high number of flexibly configurable inputs and outputs. A special feature are the generously dimensioned half bridges, which are configured as full bridges and can supply up to 24 A of electricity in parallel operation. Short-circuit proof reference and sensor supplies reduce the wiring effort. A PT1000 temperature measurement input allows use, for example, for fan controls. Programming is done in C/C++ via the STM32 CUBE IDE.

Product features

  • 32 Bit CPU > 200 MHz
  • 2 CAN interfaces
  • Programming in C/C++
  • High contiuous current
  • Configuration inputs for simplified multiple use
  • Powerful bridge outputs
  • Temperature measurement input
  • Compact design
  • Potted housing

Technical Data

CPU STM32 F7
Programming C/C++
Operating voltage range DC 8 ... 32 V, ECU voltage supplied separately
Operating / storage temperature range -40 °C ... +85 °C
Interfaces CAN 1 e.g. for CANopen®, SAE J1939, ISOBUS, ... corresponding stack
Maximum number of inputs/outputs 27
Inputs  
Analog 6; 0 ... 10 V/0 ... 20 mA, individually configurable; resolution 12 bit, input impedance 35 kΩ, load 120 Ω
Temperature sensor inputs 1; PT1000
Digital/frequency 8; input impedance 5.6 kΩ; 0.1 Hz ... 10 kHz; NPN/PNP input switchable via software
Digital/Coding 2 Coding e.g. for CAN-ID, Tristate
Outputs, diagnostic capable (short circuit, cable break)  
PWM, precision current measurement 4; 3 A, min. 10 Hz, max. 1.5 kHz; Possibility for dithering, current controlled, diagnosable, short-circuit proof; alternatively to be used as digital input active-lowinput impedance 10 kΩ; digital output 3 A
PWM, half bridge 4; 12 A, min. 10 Hz, max. 15 kHz; Possibility for dithering, diagnosable, short-circuit-proof; Possibility for two half bridges can be connected together to form a full bridge to control DC motors (open loop control), parallel connection possible
PWM, half bridge 4; 5 A, min. 10 Hz, max. 5 kHz: Possibility for dithering, diagnosable, short-circuit-proof; Possibility for two half bridges can be connected together to form a full bridge to control DC motors (open loop control), parallel connection possible
Sensor supply 3 power supplies for sensors (of which 1 x 10 V reference output)
Maximum permissible total current 24 A
Protection class IP66
Vibration ISO 16750-3
Shock ISO 16750-3
Reverse polarity protection Yes
Certifications E1 (ECE R10), CE ISO 14982
Diagnosis of the outputs short circuit, cable break