Despite its very compact dimensions, the JetControlMobile 231 compact controller has a high number of flexibly configurable inputs and outputs. A special feature are the generously dimensioned half bridges, which are configured as full bridges and can supply up to 24 A of electricity in parallel operation. Short-circuit proof reference and sensor supplies reduce the wiring effort. A PT1000 temperature measurement input allows use, for example, for fan controls. Programming is done in C/C++ via the STM32 CUBE IDE.
CPU | STM32 F7 |
Programming | C/C++ |
Operating voltage range | DC 8 ... 32 V, ECU voltage supplied separately |
Operating / storage temperature range | -40 °C ... +85 °C |
Interfaces CAN | 1 e.g. for CANopen®, SAE J1939, ISOBUS, ... corresponding stack |
Maximum number of inputs/outputs | 27 |
Inputs | |
Analog | 6; 0 ... 10 V/0 ... 20 mA, individually configurable; resolution 12 bit, input impedance 35 kΩ, load 120 Ω |
Temperature sensor inputs | 1; PT1000 |
Digital/frequency | 8; input impedance 5.6 kΩ; 0.1 Hz ... 10 kHz; NPN/PNP input switchable via software |
Digital/Coding | 2 Coding e.g. for CAN-ID, Tristate |
Outputs, diagnostic capable (short circuit, cable break) | |
PWM, precision current measurement | 4; 3 A, min. 10 Hz, max. 1.5 kHz; Possibility for dithering, current controlled, diagnosable, short-circuit proof; alternatively to be used as digital input active-lowinput impedance 10 kΩ; digital output 3 A |
PWM, half bridge | 4; 12 A, min. 10 Hz, max. 15 kHz; Possibility for dithering, diagnosable, short-circuit-proof; Possibility for two half bridges can be connected together to form a full bridge to control DC motors (open loop control), parallel connection possible |
PWM, half bridge | 4; 5 A, min. 10 Hz, max. 5 kHz: Possibility for dithering, diagnosable, short-circuit-proof; Possibility for two half bridges can be connected together to form a full bridge to control DC motors (open loop control), parallel connection possible |
Sensor supply | 3 power supplies for sensors (of which 1 x 10 V reference output) |
Maximum permissible total current | 24 A |
Protection class | IP66 |
Vibration | ISO 16750-3 |
Shock | ISO 16750-3 |
Reverse polarity protection | Yes |
Certifications | E1 (ECE R10), CE ISO 14982 |
Diagnosis of the outputs | short circuit, cable break |