We automate your success.

JetControlMobile 230

Description

Despite the compact dimensions, the JetControlMobile 230 offers a high number of flexibly configurable inputs and outputs. In its class, it sets standards in current carrying capacity and is therefore recommended in addition to the typical hydraulic applications for tasks with high continuous currents, e.g. for lighting applications. Short-circuit-proof sensor supplies reduce the wiring effort. Programming is done in C/C++ via the STM32 CUBE IDE.

Product features

  • 32 Bit CPU > 200 MHz
  • Programming in C/C++
  • High contiuous current
  • Configuration inputs for simplified multiple use
  • Compact design
  • Potted housing

Technical Data

CPU STM32 F4
Programming C/C++
Operating voltage DC 8 … 32 V, with separate ECU power supply
Operating/storage temperature -40 … +85 °C
CAN ports 1; E.g. for CANopen®, SAE J1939, ISOBUS, ... corresponding stack provided
Max. number of inputs/outputs 26
Inputs  
Analog 8; 0 … 5 V/0 … 20 mA, can be configured individually; Resolution: 12 bits, input impedance: 35 kΩ, load resistor: 120 Ω
Digital/frequency 4; Active-high; input impedance 5.6 kΩ; 0.1 Hz ... 10 kHz
Digital/CAN-coding 2 Coding e.g. for CAN-ID, Tristate
Outputs with diagnostics capability (short-circuit, no-load)  
PWM, precision current measuring 4; 3 A, 1.5 kHz max.; Possibility for dithering, current control, diagnostics capability, short-circuit proof; Alternative usage: Digital input active-low, input impedance 10 kΩ; Digital output 3 A; PNP input
PWM 6; 7 A, 1.5 kHz max.; Possibility for dithering, diagnostics capability, short-circuit proof; Alternative usage: Digital input active-low, input impedance 10 kΩ; Digital output 7 A; PNP input
Digital (50%ON period) 4; 3 A high-side, diagnostics capability, short-circuit proof, (with 50%ON period); Alternative usage: Digital input active-low, input impedance 10 kΩ; PNP input
Power supply - Sensors 3 Independent supply VBAT for sensors
Max. permitted total current 25 A
Degree of protection IP65
Vibration ISO 16750-3
Shock ISO 16750-3
Protection against polarity reversal Yes
Output diagnostics Short circuit, no-load
Certifications E1 (ECE R10), CE ISO 14982

Your contact person

Sales Department
  +49 (7141) 2550-663
  sales@bucherautomation.com

Your contact person